EMC Infrastructure for Virtual Desktops Enabled by EMC VNX Series,
VMware vSphere 4.1, VMware View 4.5, and VMware View Composer 2.5 Proven Solution Guide
26
Cisco 6509 configuration
Overview
The nine-slot Cisco Catalyst 6509-E switch provides high port densities that are ideal
for many wiring closet, distribution, and core network deployments as well as data
center deployments.
Cabling
In this solution, the ESX server and VNX Data Mover cabling are evenly spread
across two WS-x6748 1 Gb line cards to provide redundancy and load balancing of
the network traffic.
Server uplinks
The server uplinks to the switch are configured in a port channel group to increase
the utilization of server network resources and to provide redundancy. The
vSwitches are configured to load balance the network traffic on the originating port
ID.
The following is an example of the configuration for one of the server ports:
description 8/10 9048-43 rtpsol189-1
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 274,516-527
switchport mode trunk
no ip address
spanning-tree portfast trunk
Data Movers
The network ports for each VNX5300 Data Mover are connected to the 6509-E
switch. The server_2 ports cge-2-0 and cge-2-1 are configured with LACP, which
provides redundancy in case of a NIC or port failure.
The following is an example of the switch configuration for one of the Data Mover
ports:
description 7/4 9047-4 rtpsol22-dm2.0
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 274,516-527
switchport mode trunk
mtu 9216
no ip address
spanning-tree portfast trunk
channel-group 23 mode active