EMC Infrastructure for Virtual Desktops Enabled by EMC VNX Series,
VMware vSphere 4.1, VMware View 4.5, and VMware View Composer 2.5 Proven Solution Guide
27
Fibre Channel network configuration
Two Brocade DS5100 series FC switches are used to provide the storage network
for this solution. The switches are configured in a SAN A/SAN B configuration to
provide a fully redundant fabric.
Each server has a single connection to each fabric to provide load-balancing and
failover capabilities. Each storage processor has two links to the SAN fabrics for a
total of four available front-end ports. The zoning is configured so that each server
has four available paths to the storage array.
configuration
Single initiator and multiple target zoning are used in this solution. Each server
initiator is zoned to two storage targets on the array. The following diagram shows
the zone configuration for the SAN A fabric.