EMC Infrastructure for Virtual Desktops Enabled by EMC VNX Series,
VMware vSphere 4.1, VMware View 4.5, and VMware View Composer 2.5 Proven Solution Guide
59
The IOPS serviced by the individual drives in the pool were extremely low because
almost all I/O requests were serviced either by FAST Cache or EFD replicas.
The following graph shows the LUN IOPS and response time from the Pool1_3 data
store. Because the statistics from all the pools were similar, only a single pool is
reported for clarity and readability of the graph.
During peak load, the LUN response time remained within 6 ms and the data store
serviced over 300 IOPS. The majority of the read I/O was served by the replica
LUNs and not by the pool LUN.
processor IOPS
The following graph shows the total IOPS serviced by the storage processor during
the test.
Commenti su questo manuale